characteristic parameter | ||||
project | specifications | |||
IN-OUT | analog input | 2-way/voltage current signal switchable, voltage 0-10V,current 0-20mA | ||
Digital input | 5 channels/optocoupler isolation, including 1 high-speed pulse input, with a maxinum input pulse frequency of up to 100KHz | |||
analog output | 2 channels/voltage output range 1-10V, current output range 0-20mA, output signal type can be switched | |||
Digital output | 2-way/optocoupler isolation/open collector output/rated current 20mA (DO, HDO) | |||
Digital pulse output | 2 channels/optocoupler isolation/open collector pulse (frequency or PWM) output (DO, HDO), including1 channel of high-speed pulse output, the maximum output pulse frequency can reach 100KHz | |||
relay output | 2-way/Normally Open and Normally Closed Contact/250VAC-3A | |||
communication mode | Standard MODBUS-485 communication protocol | |||
control characteristic | control mode | V/F control; PG free vector control (SVC) | ||
Frequency setting mode | Multple setting methods such as keyboard setting, analog quantity seting, pulse setting, communication setting, etc | |||
Freduency control range | 0.01-400.00Hz | |||
Frequency control accuracy | Digital setting: 0.01Hz; Analog setting: maximum frequency x 0.025% | |||
speed range | 1:200(SVC); 1:1000(FVC) | |||
Steady range | ±0.5%(SVC);±0.02%(FVC) | |||
Acceleration and deceleration time | 1.0-3600.0 seconds (acceleration and deceleration times can be set separately, and S characteristics can be switched) | |||
Inching control | Point frequency range: 0.00Hz-100.00Hz; Point acceleration time: 0.0s-3600s | |||
Starting torque | 0.5Hz 150%(SVC) adjustable, considering the capacity of the frequency converter; 3.0Hz 100%(V/F) | |||
Torque boost | Automatic torque increase; Adjustable manual torque increase of 0.1%-30.0% | |||
braking torque | Braking resistance braking (125%), DC braking (20%) | |||
DC braking | Braking time: 0.0s-36.0s; Braking current: 0.0%-100.0% | |||
timing control | Timing range: 0.0min-6500min | |||
Pid control | Built in PIO function for convenient closed-loop control of processes | |||
V over F curve | Linear, multi-point custom curve, 1.1-2.0 arbitrary descent curve | |||
Multi stage speed control | Buit-in simple PLC can control the maximum 16 speed frequency logic | |||
Carrier adjustable | Adjustable from 1.0 to 16.0kHz, adjustable according to module temperature | |||
Frequency setting signal | -10-+10,0-+10,4-20mA, high-frequency pulse, PWM pulse | |||
protection function | Overload capacity | G:150% 60s 200% 3s | ||
Instantaneous overcurrent /short circuit protection | Automatically cut off output when the rated output current exceeds 200% | |||
Overyoltage/secondary voltage protection | When the DC voltage of the bus is too low (360V) or too high (800V), the motor stops freely (except during braking) | |||
Phase loss protection | When there is a phase loss at the input or output end, the motor stops freely | |||
Overheat protection | When the radiator temperature is ≥85 ℃, the motor stops freely; The temperature protection threshold can be freely set according to the ambient temperature | |||
motor protection | Analog input can be connected to temperature sensor inputs (PT100,PT000) to achieve motor overheating protection | |||
Stall protection | Using current sensors to detect stall prevention during acceleration and deceleration, and stall prevention during operation (acion current can be set) | |||
ground protection | Using current sensors for detection | |||
Instant stop | By compensating for voltage reduction through load feedback energy, the frequency converter can maintain continuous operation for a short period of time | |||
specifications stucture | Rated input | voltage:1/3PH 220V±20%;3PH 380V±20%;frequency:50Hz/60Hz±5% | ||
Cooling and protection | ≤18.5kW:IP20;>18.5kW:1IP10;Forced air cooling | |||
Usage environment | Temp:-10℃-+40℃ altitude: Not higher than 1000m; Indoor,without corrosive gases | |||
Save Environment | Temp:-20℃-+65℃ humidity: 20-90%RH(No condensation)The vibration is less than 6m/S squared(0.6g) | |||